Magtrol  
Motor Test Equipment
Dynamometers
Hysteresis
-Specifications
 
 
PRODUCTS
SERVICES
SUPPORT
DATA SHEETS
COMPANY
CONTACT
SITE MAP
 

Hysteresis Dynamometer Specifications

 
For complete technical specifications, power curves and general dimension drawings, download the data sheet. For detailed dimension drawings… Conversion Calculators

Click on the pdf icon in the table below. A PDF document will open in a new window.
(Adobe Acrobat Reader 7.0, or later, is required.)
 
*Please contact sales regarding any dynamometer application requiring the use of a controller other than the DSP 6001 or DSP 7000 Series*
MODEL Torque
Measure
Unit Code
Maximum
Torque
Range
Maximum
Speed
Kinetic Power Brake
Cooling
Method
View Drawing
5 minute continuous* short
base plate
short
base plate
long
base plate
long
base plate
T-slot
base plate
rpm W W PDF STEP PDF STEP PDF
HD-106 5N³ 0.018 N·m 30,000 35 7 Convection get drawing get drawing N/A
HD-100 5N³ 0.08 N·m 25,000 75 20 Convection get drawing get drawing N/A
HD-400 5N³ 0.28 N·m 25,000 200 55 Convection Get drawing Get drawing N/A
HD-500 5N³ 0.85 N·m 25,000 400 80 Convection Get drawing Get drawing N/A
HD-510 5N³ 0.85 N·m 25,000 750 375 Compressed
Air¹
Get drawing Get drawing N/A
HD-505 5N³ 1.7 N·m 25,000 800 160 Convection Get drawing Get drawing N/A
HD-515
5N³ 1.7 N·m 25,000 1,500 900 Compressed
Air¹
Get drawing Get drawing N/A
HD-700 5N³ 3.10 N·m 25,000 700 150 Convection Get drawing Get drawing N/A
HD-710 5N³ 3.10 N·m 25,000 1,500 935 Blower² Get drawing Get drawing N/A
HD-705 5N³ 6.20 N·m 25,000 1,400 300 Convection Get drawing Get drawing N/A
HD-715 5N³ 6.20 N·m 25,000 3,400 3,000 Blower² Get drawing Get drawing N/A
HD-800 5N³ 14.00 N·m 12,000 2,800 1,800 Compressed
Air¹
Get drawing Get drawing Get drawing
HD-810 5N³ 14.00 N·m 12,000 3,500 3,000 Blower² Get drawing Get drawing Get drawing
HD-805 5N³ 28.0 N·m 12,000 5,300 3,000 Compressed
Air¹
Get drawing Get drawing Get drawing
HD-815 5N³ 28.0 N·m 12,000 7,000 6,000 Blower² Get drawing Get drawing Get drawing
HD-825 5N³ 56.5 N·m 8,000 14,000 12,000 Blower² Get drawing Contact
Magtrol
Contact
Magtrol
Contact
Magtrol
 

* NOTE: Operating at the continuous power rating for periods of up to 4 hours is acceptable.  However, operating for extended periods at high temperatures will result in premature component and bearing failure. Limiting the length of the cycle and the component temperatures will guard against premature failure. Where continuous duty is desired for longer time intervals, component temperatures should be maintained less than 100°C; monitoring the outside brake surface temperature is a sufficient reference.


¹
 Model HD-510, HD-515, HD-800 and HD-805 Dynamometers require air cooling provided by user. Regulator and filter package is provided as standard equipment on these units. See catalog for pressure ratings.
²  Blower package is included as standard equipment with Model HD-710, HD-715, HD-810, HD-815 and HD-825 Dynamometers.
³ 5 Volt Output
 
 
**Click Here for 6N (English), 7N (Metric) and 8N (SI) Specifications**
Back to top
 
Magtrol, Inc (USA): 716-668-5555 • magtrol@magtrol.com ~ Magtrol SA (Switzerland): 41 (0)26 407 3000 • magtrol@magtrol.ch
Magtrol Contact Us English French German Chinese India Russian Motor Test Equipment Torque Transducers Load-Force-Weight Systems Brakes and Clutches Displacement Rotary Transmitters